Calculated Exhaust Flow Rate

Calculated Exhaust Flow Rate for a Silencer With Pressure Drop of 1.0" Hg or Less

If pressure drop requirement is 1" of Hg or less and exhaust flow rate (CFM) is known, the following chart can be used to determine silencer size without calculations.  Find the lowest flow rate on the chart that is equal to or greater than the flow rate of your engine under the appropriate silencing level.

Inlet Pipe Area (Ft 2)

Pipe Dimension

100 Level Silencer

200 Level Silencer

300 Level Silencer

400 Level Silencer

.0031

.75

41

35

29

-

.0055

1

73

63

52

-

.0085

1.25

113

98

80

-

.0123

1.5

163

142

117

-

.0218

2

288

250

206

-

.0341

2.5

450

380

325

-

.0491

3

650

565

470

-

.0668

3.5

880

770

640

-

.0873

4

1160

1000

830

790

.1363

5

1810

1580

1290

1240

.1963

6

2600

2250

1870

1770

.3491

8

4600

3900

3340

3150

.5454

10

7200

6200

5200

4950

.7854

12

10200

8800

7500

7100

1.069

14

14000

12000

10200

9700

1.438

16

18000

15500

13700

13000

1.760

18

23000

19800

16800

16000

2.180

20

28400

24300

20900

19700

2.640

22

34400

29500

25300

24000

Note:
These precalculated exhaust flow rates are based on an end in end out silencer.  Please refer to specific specification sheet when determining back pressure for a side inlet or middle side inlet silencer.*